    Quote Originally Posted by RobertP View Post
    On the generator subject two things that are very important for the life of your equipment and your generator. First of all NEVER run any generator more than 80% of it's running watt rating. That little guy says 1000 watts but the running watts are actually 900. That means 80% of it is only 720 watts. Check to see how many watts your system is running....yeah you could turn off some of the lights and only run the heater periodically but try to stay under. What happens if you go over? Depends on the generator. If it even will go over 80% most are not designed to do it for more than a few seconds to a minute. Think of the power drain on a power saw...it pulls it's max rating at startup and then settles back to use less power. That is why generators are rated like they are. Well many cheap generators SAY they will run X number of watts and just get nowhere close to that number. I have a cheap Harbor Freight 3500 watt genny that will barely push 2500 watts before it dies. But it will run power tools and works great out on the farm...and since it was $200 it is hard to get too mad. However, my Yamaha says 2900 and it will do 2900 before it overloads and shuts down. I use this in emergencies and based on my apex will easily run the tank and my refrig if the heaters done kick in while the refrig is running. The Yamaha lists for $1500 but you would be surprised how many used gennys are in the Gulf coast area! Keep those running watts below 80% and the generator will last a very long time.

    The other important thing is you CANNOT run sensitive equipment with a cheap non-inverter type generator. I cannot stress this enough. Lost a refrigerator during Ike to a non-inverter Generac genny and no way in hell I will hook up my Apex to one. The inverter cleans up the power so you can charge a phone or laptop or an Apex. You could use the old style to run a battery charger and then run off battery but there is some loss there as well. By the way I LOVED that Generac 4000 generator...was a real workhorse and started on the first pull as long as it didn't sit too long between uses.

    Sorry to get off topic. I could talk for a while about old gas...the crappy ethanol in our fuels...running the genny out of gas....
    Great info Robert! I bought an inverter generator... It was nice knowing I could plug my phone into it without blowing up my phone. Plus, it ran forever on 1 gallon of gas. It was way more expensive though than the regular generators but I figured I could use it for other purposes such as tailgating or camping one day.

  2. #22
    BOD MEMBER PorpoiseHork's Avatar
    Join Date
    Apr 2017
    Location
    Spring Branch
    Posts
    385
    Post Thanks / Like
    Post Thanks / Like
    Quote Originally Posted by ATXacrofarmer View Post
    He mentioned living in an apartment and them not allowing generators I believe. Otherwise, I'd lean towards the generator too.

    The issue I see with solely relying on a generator is what happens in the event of a power failure when no one is at the house/apt? With a small battery backup unit it will provide power to one or more DC pumps for multiple hours until you can get the generator up and running. This would come into play if there is a temporary power outage during the day when you're at work, or if a bad storm is rolling through and may not be the ideal time to be outside fiddling with a generator. That's why having a small battery backup that will take over the instant a loss of power happens giving you time to act.
    Bret
    M.A.R.S.H. - Board Member
    Marine Aquarium and Reef Society of Houston

  3. Likes FarmerTy, RR-MAN liked this post
  4. #23
    MARSH Sponsor FarmerTy's Avatar
    Join Date
    May 2015
    Location
    Austin, TX
    Posts
    2,211
    Post Thanks / Like
    Post Thanks / Like
    Quote Originally Posted by PorpoiseHork View Post
    The issue I see with solely relying on a generator is what happens in the event of a power failure when no one is at the house/apt? With a small battery backup unit it will provide power to one or more DC pumps for multiple hours until you can get the generator up and running. This would come into play if there is a temporary power outage during the day when you're at work, or if a bad storm is rolling through and may not be the ideal time to be outside fiddling with a generator. That's why having a small battery backup that will take over the instant a loss of power happens giving you time to act.
    My situation works well with a generator combined with several battery powered air pumps. The pumps will get me through the immediate until the weather gets better and I can run the generator.

    I do have a unique schedule of working from home and having a good reefing buddy down the street when I go on vacations that can watch the tank.

    The battery powered options are nice to have for the reasons you mentioned. My only knock on them is that they have a limited life span, like UPSs, and will have to be replaced periodically. $100 every 2-4 years is definitely good insurance but I'd rather put that money towards a generator that has a longer life span.

    To each their own but those are the reasons I went with a generator instead of a battery back up.

  5. #24
    Supporting Member
    Join Date
    Oct 2017
    Location
    Columbus, TX
    Posts
    58
    Post Thanks / Like
    Post Thanks / Like
    I really like battery backups as WELL as a generator! I have/had a UPS on the tank that will run it is short time and this will give me time to get the portable generator in place, fire it up, and run a power cord to the tank. There is no doubt that batteries have a relatively short life which is why I dont like to spend much money on them.

  6. #25
    MARSH GUEST
    Join Date
    May 2014
    Posts
    201
    Post Thanks / Like
    Post Thanks / Like
    Quote Originally Posted by Early Cuyler View Post
    Hello Marshians

    Needing some advise on battery back up for my 40 gallon breeder. Not sure what to look for or direction to go. Anyone have any tips or recommendations? I have 2 Jabeao Wave Makers and an Aquamaxx HOB skimmer plus lights. No sump at this time. Thank you in advance.
    I only use 3 Air pumps for my 220g tank and it shut out all the power of my big UPS backups in one night.
    If you want to run wavemaker, skimmer, plus lights, how many battery backups can handle for one night?

  7. #26
    BOD MEMBER PorpoiseHork's Avatar
    Join Date
    Apr 2017
    Location
    Spring Branch
    Posts
    385
    Post Thanks / Like
    Post Thanks / Like
    It really depends on how you have ity setup. If you're relying on standard computer UPS backups, then the best you can expect is a few hours with a low draw DC pump. Computer UPS units were never intended to provide long duration power to the devices connected to them. They are there to provide just enough reserve time to prevent system damage and/or data loss in short duration power outages, and to allow you to safely shut down your hardware. They also use a significant percentage of the battery reserve just powering the small 12/24v DC battery(s) to 110v AC. So when using them on an aquarium is OK in short term outages as well as protecting the more sensitive components from power surges they just cannot provide the sustained power a reef tank requires. The only way to increase the run-time on a standard computer UPS is to modify it and increase the battery reserve from the tiny 8-10AH that is common for most of these units to at least 70AH deep cycle battery. Even then you would be hard pressed to provide enough reserve time to power everything on your system especially lights and heaters as you're looking at a range of 200-500 watts or more just for these alone. Provided the UPS inverter is a 12v unit you would need at a minimum of 4 to 6 70AH 12V batteries wired in parallel to provide the reserve to power all the components listed.

    A much better and easier to implement option is provide short term backup for less critical systems such as lights, skimmer, and heaters as your tank can run without these for several hours and suffer little to no effects on your tank inhabitants. Corals and fish can easily go 2-3 days with little to no light before you have to provide light. For the heaters, it all depends on how big the tank is, and the ambient temp. The larger the tank and warmer the room, the slower the temperature falls.

    Personally I think where one should focus the attention on is the main pump and/or circulation wave maker units. Co2 levels could climb very rapidly in a heavily stocked tank, and within a couple hours the more sensitive fish could become stressed and even die. With DC pumps now readily available setting up a battery backup for these is far simpler a task and can easily provide upwards of 48 or more hours of emergency power to the pumps with little to no modifications in some cases. For example the CoralBox (Jebao) battery unit can easily power a pair PP-8 series (Current EFlux 1050) or similar dc wave pump for upwards of 24 hours. These units are easily scalable or if you are up for it, can be modified to accept external power from a second battery pack increasing the reserve time to 72 or more hours. With pumps that require 24v to operate like some of the EcoTech's and such, you can wire in a voltage booster that ups the 12v to 24-36v depending on the requirements of your main pump(s). and tie them in as well.
    Bret
    M.A.R.S.H. - Board Member
    Marine Aquarium and Reef Society of Houston

  8. Likes tthouston liked this post

Similar Threads

  1. Battery back ups
    By Tiffany in forum Pumps
    Replies: 4
    Last Post: 09-16-2016, 03:17 PM
  2. Ecotech Back-up Battery
    By Ccscorpion200 in forum Marine and Reef General Discussion
    Replies: 3
    Last Post: 01-21-2016, 04:03 PM
  3. Replacing battery on Vortech battery back-up
    By OceansX in forum Do-it-Yourself
    Replies: 4
    Last Post: 04-02-2013, 02:51 PM
  4. Mp40wes with back up battery
    By cu0ngsayz in forum Pumps
    Replies: 1
    Last Post: 10-11-2012, 04:32 PM
  5. My Diy Battery Back Up Pump
    By mike13oy in forum Do-it-Yourself
    Replies: 11
    Last Post: 02-02-2011, 12:49 PM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •